Motor Starting

Network Performance & Protection

Motor starting studies evaluate system voltage dips, motor acceleration torque, starting duration, and running load stability during the startup of large medium-voltage and low-voltage electric motors. MEPCO identifies voltage sag mitigation strategies and verifies starting methods to prevent motor stall, contactor drop-out, and generator tripping.

Motor Starting

Figure 1: MEPCO electrical engineers evaluating medium-voltage motor control center (MCC) starting performance.

Technical Scope & Engineering Capabilities

MEPCO Engineering Projects brings specialized domain knowledge, rigorous modeling standards, and practical site experience to every assignment. Our scope covers:

  • Dynamic Voltage Sag Analysis: Calculating transient voltage dips at the motor terminals, auxiliary buses, and Point of Common Coupling (PCC) during motor startup.
  • Motor Acceleration Simulation: Evaluating motor speed vs. torque, acceleration time, load torque curve, and thermal withstand limit curves under reduced voltage conditions.
  • Starting Method Optimization: Evaluating and comparing Direct-On-Line (DOL), Star-Delta, Auto-transformer, Soft Starter, and Variable Frequency Drive (VFD) configurations.
  • Running Load Impact: Assessing the impact of motor inrush currents on already-running motors, sensitive electronic equipment, and lighting networks.
  • Generator-Fed Starting: Evaluating voltage and frequency response when large motors are started on emergency diesel generator supplies.
Software Platforms & Computational Tools

Primary Tool: ETAP Dynamic Motor Acceleration & Starting Analysis Module.

Simulation Modes: Static Motor Starting (locked-rotor impedance method) and Dynamic Motor Acceleration (torque-slip curve and mechanical load model).

Applicable Standards & Grid Codes

Standards: IEEE 399 (Brown Book), NEMA MG-1 (Motors and Generators), IEC 60034-12 (Starting performance of single-speed three-phase cage induction motors).

Methodology & Project Delivery Workflow

Our engineering delivery aligns with MEPCO’s structured 6-stage project execution framework, ensuring quality throughout input verification, design modeling, and client handover:

  1. Stage 01 — Scope & Criteria Definition: Establish study boundaries, utility tie-in data, single-line diagrams, and client objectives.
  2. Stage 02 — Data Audit & Modeling Assumptions: Collect, verify, and validate manufacturer datasheets, impedance tolerances, and site operating configurations.
  3. Stage 03 — Simulation Model Development: Build detailed, validated mathematical digital models in specialized power software.
  4. Stage 04 — Computational Analysis & Verification: Execute base-case and contingency scenarios, conducting rigorous internal peer reviews.
  5. Stage 05 — Client Review & Approval: Present study findings, address technical comments, and participate in technical clarification sessions.
  6. Stage 06 — Final Handover: Deliver formal certified engineering reports, executive summaries, and native simulation model files.
Motor Starting

Figure 2: Medium-voltage motor feeder switchgear with soft starter and protection interfaces.

Completed Project References (From MEPCO Profile)

Selected project assignments delivered by MEPCO demonstrating our technical execution and regional client trust:

Project Name Client / Authority Location Tools / Mode Scope Executed
SPCO (North & South) Plant Saudi Chevron (S-Chem) Saudi Arabia ETAP Dynamic Motor Starting Analysis for heavy process compressor and pump induction motors.
JCP Plant Saudi Chevron (S-Chem) Saudi Arabia ETAP Motor Starting & Acceleration Studies under multiple operating configurations.
SCP Plant Saudi Chevron (S-Chem) Saudi Arabia ETAP Large MV Induction Motor Acceleration and System Voltage Recovery Analysis.
GAS-Jubail Industrial Plant National Industrial Gases Company Saudi Arabia ETAP Process Motor Starting and Voltage Dip Mitigation Study.
Air Liquide Industrial Plant Air Liquide Egypt ETAP Industrial Gas Compressor Motor Starting and Bus Voltage Drop Evaluation.
Key Engineering Deliverables & Outputs:
  • Motor Acceleration Study Report with transient voltage and current profiles vs. time.
  • Motor Speed vs. Torque Acceleration Curves compared against load torque requirements.
  • Voltage Drop Summary Sheets at motor terminals and upstream distribution buses.
  • Starting Method Comparison Matrix and Soft Starter / VFD sizing recommendations.
  • Thermal Stall Withstand Verification Curves.